Liquid Level Transmitters

Documents

Order by : Name | Date | Hits [ Ascendant ]

TeleSensor TeleSensor

Date added: 05/08/2012
Date modified: 02/15/2013
Filesize: 958 kB
Downloads: 9325

telesensor

•  External Mounting at Tank
•  Unaffected by Foam or Vapor
•  Electronic (4-20 mA) or Pneumatic Output

KING-GAGE® TeleSensor detects level by sensing hydrostatic pressure created by liquid depth. Acting on the force balance principle, a sensitive diaphragm is exposed to the liquid contents of the tank. Compressed air within the sensor creates a pneumatic pressure that balances the force of the liquid acting against the diaphragm. This diaphragm unit is generally paired with the 868 D/P Sensor Control with integral transmitter. This converts the pneumatic isolation pressure to a proportional 4-20 mAdc signal suitable for process control or remote level indication.

The basic configuration is intended for pipe flange connection mounting (2", 3" or 4" class 150 ANSI) to any typical outlet near the bottom of the tank. TeleSensor units are virtually free from long term drift, hysteresis, and temperature sensitivity unlike strain measurements (including load cells) since mechanical deflection of the diaphragm is not directly measured. Additionally, pressure based measurement is unaffected by liquid foam or vapor layers within the tank.

KING-GAGE TeleSensor units combine accuracy, rugged durability, reduced maintenance, and long term stability for liquid level tank gauging. A compressed air/gas supply is required for operation of the sensor. Entirely pneumatic versions are available for use in hazardous area service eliminating need for additional intrinsic safety provisions.

telesensorsystem

1100-20_telesensor-thumb

For a pdf of the TeleSensor Data Sheet, click the 'Download' button below.

Tank Mount Fittings and Adapters Tank Mount Fittings and Adapters

Date added: 01/06/2009
Date modified: 02/15/2013
Filesize: 434.88 kB
Downloads: 11907

adapters

• Weld In Shell for Flush Fit
• Adapt Existing Fittings for Retrofit
• Accommodates AcraSensor or Electronic Sensor

A variety of mounting options are provided by our selection of weld in shells, quick release fittings or adapters. These include retrofitting tanks having other original manufacturers sensor mountings. Of course, KING-GAGE® weld in shells are available installed by most leading tank manufacturers.

ex-1690_adapters-thumb

For a pdf of the Adapters Data Sheet, click the 'Download' button below.

Purge Control Purge Control

Date added: 01/04/2009
Date modified: 02/15/2013
Filesize: 509.29 kB
Downloads: 9268

purgecontrol780

• Continuous Level Measurement
• Simple Proven Sensing Technique
• Suitable for Corrosive or Aggressive Liquids

When purged with compressed air, liquid within a downpipe extending into the tank is displaced by air pressure equal to the hydrostatic force created by liquid depth. If carefully regulated at a low rate of flow, air pressure will constantly maintain equilibrium against the force of the liquid. Output is proportional to liquid depth and can be transmitted as an electronic 4-20 mA signal or pneumatically as a direct 1:1 pressure signal.

788 D/P Purge Control is a differential pressure regulator and air flow control. It generates a constant flow of compressed air to purge a downpipe. Its integral differential pressure transmitter provides 4-20 mAdc output proportional to liquid level.

APPLICATION NOTE: Available in all-pneumatic configurations for hazardous area service.

1200-25_purge

For a pdf of the Purge Control Data Sheet, click the 'Download' button below.

LiquiSeal Purge Control LiquiSeal Purge Control

Date added: 01/05/2009
Date modified: 02/15/2013
Filesize: 571.03 kB
Downloads: 7911

dp738

• Continuous Level Measurement
• Simple Proven Sensing Technique
• Suitable for Corrosive or Aggressive Liquids

When purged with compressed air, liquid within the downpipe is displaced by air pressure equal to the hydrostatic force of liquid in the tank. If carefully regulated at a low rate of flow, air pressure will constantly maintain equilibrium against the force of the liquid. Output is proportional to liquid depth and can be transmitted as an electronic 4-20 mA signal or pneumatically as a direct 1:1 pressure signal.

LiquiSeal D/P purge control is a fully integrated air purge regulator and level transmitter. Operation is based on the control regulating a continuous 1 cfh (cubic foot per hour) flow of compressed air into the tank downpipe. An internal differential pressure sensor element converts resulting pressure into a 4-20 mAdc two wire signal.

APPLICATION NOTE: Available in all-pneumatic configurations for hazardous area service.

1200-25_purge

For a pdf of the LiquiSeal Data Sheet, click the 'Download' button below.

LevelWAV level radar LevelWAV level radar

Date added: 08/09/2017
Date modified: 08/09/2017
Filesize: 654.3 kB
Downloads: 512

• Advanced Smart Radar Improves Reliability
• Compact Size for New or Retrofit Applications
• Sanitary Configurations for Food & Dairy

KING-GAGE® LevelWAV is suitable to a broad range of level measurement and control applications including process conditions exhibiting visible vapors, foam, high termperature and/or pressure. Level measurement is possible for highly corrosive materials (caustics, acids, solvents) and slurries.

With no moving parts or direct product contact, LevelWAV transmitters eliminate the maintenance requirements of other level technologies. The compact size and mounting footprint makes tank top mounting suitable for even tight spaces. Radar level measurement is a practical solution in retrofit applications to replace failing or erratic level transmitters. Model offerings include sanitary configurations with stainless steel construction and food-grade PTFE antenna (Tri-Clamp mountings available).

Applications include food/beverage, pharmaceutical, pulp/paper, water/wastewater and chemical processing.

For a pdf of the TeleSensor Data Sheet, click the 'Download' button below.

<< Start < Prev 1 2 Next > End >>