  • 4 mA to 20 mA output for broad compatibility
  • Better than ±0.02% span repeatability
  • Piezoresistive technology for enhanced stability
  • Also offered in hybrid versions combined with an air flow control for pneumatic sensors or downpipe (bubbler) systems

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SERIES 868 D/P Sensor Control (Air Flow Control)
FITINGS 19 None, 1/4” NPT 39 Polyflo; (4) 1/4” tube 49 Swagelok; (4) 1/4" tube
(compatible with copper or poly tubing)
MILLIAMP OUTPUT 108 4 mAdc to 20 mAdc 0-5 psid 128 4 mAdc to 20 mAdc 0-15 psid 148 4 mAdc to 20 mAdc 0-50 psid
118 4 mAdc to 20 mAdc 0-10 psid 138 4 mAdc to 20 mAdc 0-30 psid 168 4 mAdc to 20 mAdc 0-2 psid

NOTE: Unit includes (1) water-resistant Hubbell cord grip.

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

Output signal 4 mAdc to 20 mAdc (milliamperes)
Accuracy ±0.2% FS (±0.10% F.S., typical) includes non-linearity, hysteresis and non-repeatability
Repeatability ±0.20% of calibrated span
Temperature range 0 °F to 180 °F/-18 °C to 82 °C
Compensated temperature range 32 °F to 120 °F/ 0 °C to 54 °C
Thermal effects (over
compensated temperature range)
Less than .007% °F (.011% °C) span shift—sensitivity
Less than .007% °F (.011% °C) span shift—zero
Power requirement* 14 Vdc to 40 Vdc
Power supply stability
(effect on FSO)
Less than .005% of span change in output per volt change at input terminals
Burst pressure 200 psi
Combined accuracy** 0–5 psid trans./control
0–10 psid trans./control
0–15 psid trans./control
0–30 psid trans./control
0–50 psid trans./control
±0.34% full scale
±0.27% full scale
±0.24% full scale
±0.22% full scale
±0.21% full scale
Compressed air requirement 35 psid to 150 psig supply pressure at control inlet
Maximum depth measurement 1,937 inH2O (49.0 m water)

* Unregulated
** Combined accuracy refers to the primary accuracy of the sensor in combination with the secondary accuracy of the D/P transmitter.

Options & Accessories

7333-10 Replacement filter element
7334-2 SafeGard service kit
7334-9 Air control section kit
7879-20 Vent generator
9316-4 O-ring for D/P top plate (868)

    
        
        
        
        