Level Transmitters

Home » Products » Level Transmitters » Electronic » 550 Series ES2 Slimline Level Transmitter

550 Series ES2 Slimline Level Transmitter

  • Designed for inventory monitoring
  • Robust protection in washdown environments
  • Continuous liquid level measurement
  • Excellent stability and repeatability
  • Two-wire loop powered (4 mA to 20 mA)
  • Available retrofit adapters include Cherry-Burrell LevelMatic, Anderson Instrument, Rosemount / Foxboro, Tank Mate and Wizard

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

ORDERING INFORMATION

SERIES 550          
MOUNTING APPLICATION 1 Short mount (single wall,
non-insulated tank)
2 Standard mount (insulated wall up to
4.5"/114 mm; or adapter for non-KING
"short" shell)
3 Long mount (insulated wall up to
6.75"/171 mm; or adapter for non-KING
"standard" shell)
CONNECTION/TERMINATION 3 Cable with integral molded
connector (M12)
       
PRESSURE RANGE 05 0-5 psig/0-0.3 bar 15 0-15 psig/0-1.03 bar 50 0-50 psig./0-3.44 bar
10 0-10 psig/0-0.69 bar 30 0-30 psig/0-2.06 bar    

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SPECIFICATIONS
Span adjustment range* Nominal Minimum Range of Adjustment
0-5 psig 0-3 psig 0–83 inH2O through 0–138 inH2O/
0–2.1 m through 0–3.5 m water
0-10 psig
 
0-3 psig 0–83 inH2O through 0–277 inH2O /
0–2.1 m through 0–7.0 m water
0-15 psig 0-3 psig 0–83 inH2O through 0–415 inH2O /
 0–2.1 m through 0–10.5 m water
0-30 psig 0-10 psig 0–277 inH2O through 0–830 inH2O /
0–7.0 m through 0–21.0 m water 
0-50 psig 0-15 psig 0–415 inH2O through 0–1384 inH2O / 
0–10.5 m through 0–35.1 m water
Operating limit (maximum pressure) Pressure above 300% nominal range (over-range) will result in
damage to the transmitter (200% may cause a shift in calibration).
Accuracy Less than ± 0.20% full scale (Includes linearity, hysteresis,
non-repeatability errors)
Pressure media Gas or liquids compatible with 316 Stainless Steel (diaphragm);
Silicone rubber (o-ring). All other wetted parts 316L.
Electrical Input (excitation): 14 Vdc to 40 Vdc
Output (mAdc): 4 mA to 20 mA
Linearity (worst case) Less than ± 0.13% full scale
Hysteresis (worst case)
Less than 0.05% full scale
Non-repeatability (worst case) Less than 0.02% full scale
Operating temperature range 0 °F to 175 °F / -17 °C to 79 °C

*  Transmitter turndown ratio is 3:1 for the 0–15 psig, 0–30 psig and 0–50 psig nominal ranges. 
IMPORTANT! Accuracy, linearity, and non-repeatability values are based on nominal range. 

Options & Accessories

1747-40 FKM O-ring
1751 Clamp nut
6495-125 O-ring, housing end cap seal
6554-40 O-ring, silicone rubber (standard) 
6554-44 O-ring, oversized (special application)
5378-2-1 Field wireable connector (M12) 4-pin female w/ color reference
5630-5 FRP junction enclosure (includes 2 cable fittings)
8027-10 ES2 molded cable w/ integral M12 plug connector (32 ft /10 m) on one end
8027-25 ES2 molded cable w/ integral M12 plug connector (82 ft / 25 m) on one end

Downpipe Check ValveDownpipe Check Valve

6363 Downpipe float check valve, 3/4” NPT connections
6563-10 Downpipe float check valve, 3/4” NPT outlet, 3/8” tube inlet

   

  • Prevents siphoning or backflow of liquid through a downpipe installed in tank level gauging applications
  • Utilizes a specially designed float pin that rises up to seal the valve shut when liquid enters from the downpipe through the bottom of the unit
  • The advantage of a float check is that it doesn’t create a pressure drop that would affect the level gauge reading (Spring-loaded check valves can impact the accuracy of a downpipe or bubbler system if installed at the tank entry point)

NOTE: Not recommended for use with heavy diesel fuel oil or other high viscosity liquids. Installation in conjunction with a gate valve will permit removal of check valve for inspection and cleaning. (We recommend cleaning the check valve once per year to ensure reliability.)

Material: 304 Stainless Steel, Nylon (float), FKM (seals)
Max. Pressure: 150 psig
Inlet/Outlet: 3/4" NPT-female
Weight: 1.2 lb (0.5 kg) 

 

Download 6563 Downpipe Check Valve Data Sheet_1200-30

Available in 304 SS only

5872-1-2    Adapter, NPT-M (male) thd, use std. sensor
5872-2-2    Adapter, NPT-F (female) thd, use std. sensor

5878-1       Short Anderson shell, use standard sensor
5878-2       Long Anderson shell, use long sensor

Download Installation Instructions

Adapters available in 304 SS only

5640-1       Short Cherry-Burrell shell, use standard sensor
5640-2       Long Cherry-Burrell shell, use long sensor

Download the Installation Instructions

5665-1   Continental/Floe/Wizard shell, use standard sensor

Download Installation Instructions

5527-3        2”- flange 316L Stainless, short mount
5527-5        1-1/2”- flange 316L Stainless, short mount
5527-13      3”- flange 316L Stainless, short mount
5527-15      1”- flange 316L Stainless, short mount
5527-23      4”- flange 316L Stainless, short mount
5627-3        2”-150 class 316L Stainless flange, std mount
5627-13      3”-150 class ANSI, 316L Stainless
5627-23      4”-150 class ANSI, 316L Stainless
 

Flush Weld Tank Shell

1777-2   Weld-in tank shell, short length sensor, 316L SS, length 1-7/8” (48 mm)
Use for single wall (non-insulated) tank only!
1777 Weld-in tank shell, std length sensor, 316L SS, length 6-1/4” (159 mm)
Use for single wall or insulated wall up to 4-1/2” thick
1777-3   Weld-in tank shell, long length sensor, 316L SS, length 8-1/2” (216 mm)
Use for insulated wall up to 6-3/4” thick

 

Download Installation Instructions

5905-1     2” Ext. Foxboro/Rosemount, use standard sensor *
5905-2     6” Ext. Foxboro/Rosemount, use long sensor *

* Minimum 5 pcs order required (special)

1749-35-1    Liquid scale adapter package, use long sensor

5668-1    Short mount fixture
5668-2    Standard mount fixture
5668-3    Long mount fixture

2584-4   Shell plug, fits short shell
2584-3 Shell plug, fits standard shell, tri-clamp,
& short adapters
2584-6 Shell plug, fits long shell, long adapters

5664-1    Shell face protector, fits all weld-in shells

5641-1       Short Tank-Mate shell, use standard sensor
5641-2       Long Tank-Mate shell, use long sensor

1749-25    Tri-clamp MP-2”, 316L Stainless Steel; short length sensor
1749-27    Tri-clamp MP-2”, 316L Stainless Steel; standard length sensor

WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov