If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SERIES | 550 | |||||
MOUNTING APPLICATION | 1 | Short mount (single wall, non-insulated tank) |
2 | Standard mount (insulated wall up to 4.5"/114 mm; or adapter for non-KING "short" shell) |
3 | Long mount (insulated wall up to 6.75"/171 mm; or adapter for non-KING "standard" shell) |
CONNECTION/TERMINATION | 3 | Cable with integral molded connector (M12) |
||||
PRESSURE RANGE | 05 | 0-5 psig/0-0.3 bar | 15 | 0-15 psig/0-1.03 bar | 50 | 0-50 psig./0-3.44 bar |
10 | 0-10 psig/0-0.69 bar | 30 | 0-30 psig/0-2.06 bar |
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SPECIFICATIONS | |||
Span adjustment range* | Nominal | Minimum | Range of Adjustment |
0-5 psig | 0-3 psig | 0–83 inH2O through 0–138 inH2O/ 0–2.1 m through 0–3.5 m water |
|
0-10 psig |
0-3 psig | 0–83 inH2O through 0–277 inH2O / 0–2.1 m through 0–7.0 m water |
|
0-15 psig | 0-3 psig | 0–83 inH2O through 0–415 inH2O / 0–2.1 m through 0–10.5 m water |
|
0-30 psig | 0-10 psig | 0–277 inH2O through 0–830 inH2O / 0–7.0 m through 0–21.0 m water |
|
0-50 psig | 0-15 psig | 0–415 inH2O through 0–1384 inH2O / 0–10.5 m through 0–35.1 m water |
|
Operating limit (maximum pressure) | Pressure above 300% nominal range (over-range) will result in damage to the transmitter (200% may cause a shift in calibration). |
||
Accuracy | Less than ± 0.20% full scale (Includes linearity, hysteresis, non-repeatability errors) |
||
Pressure media | Gas or liquids compatible with 316 Stainless Steel (diaphragm); Silicone rubber (o-ring). All other wetted parts 316L. |
||
Electrical | Input (excitation): 14 Vdc to 40 Vdc Output (mAdc): 4 mA to 20 mA |
||
Linearity (worst case) | Less than ± 0.13% full scale Hysteresis (worst case) Less than 0.05% full scale |
||
Non-repeatability (worst case) | Less than 0.02% full scale | ||
Operating temperature range | 0 °F to 175 °F / -17 °C to 79 °C |
* Transmitter turndown ratio is 3:1 for the 0–15 psig, 0–30 psig and 0–50 psig nominal ranges.
IMPORTANT! Accuracy, linearity, and non-repeatability values are based on nominal range.
1747-40 | FKM O-ring |
1751 | Clamp nut |
6495-125 | O-ring, housing end cap seal |
6554-40 | O-ring, silicone rubber (standard) |
6554-44 | O-ring, oversized (special application) |
5378-2-1 | Field wireable connector (M12) 4-pin female w/ color reference |
5630-5 | FRP junction enclosure (includes 2 cable fittings) |
8027-10 | ES2 molded cable w/ integral M12 plug connector (32 ft /10 m) on one end |
8027-25 | ES2 molded cable w/ integral M12 plug connector (82 ft / 25 m) on one end |
6363 | Downpipe float check valve, 3/4” NPT connections |
6563-10 | Downpipe float check valve, 3/4” NPT outlet, 3/8” tube inlet |
NOTE: Not recommended for use with heavy diesel fuel oil or other high viscosity liquids. Installation in conjunction with a gate valve will permit removal of check valve for inspection and cleaning. (We recommend cleaning the check valve once per year to ensure reliability.)
Material: | 304 Stainless Steel, Nylon (float), FKM (seals) |
Max. Pressure: | 150 psig |
Inlet/Outlet: | 3/4" NPT-female |
Weight: | 1.2 lb (0.5 kg) |
Download 6563 Downpipe Check Valve Data Sheet_1200-30
5878-1 Short Anderson shell, use standard sensor
5878-2 Long Anderson shell, use long sensor
Download Installation Instructions
Adapters available in 304 SS only
5640-1 Short Cherry-Burrell shell, use standard sensor
5640-2 Long Cherry-Burrell shell, use long sensor
Download the Installation Instructions
5527-3 2”- flange 316L Stainless, short mount
5527-5 1-1/2”- flange 316L Stainless, short mount
5527-13 3”- flange 316L Stainless, short mount
5527-15 1”- flange 316L Stainless, short mount
5527-23 4”- flange 316L Stainless, short mount
5627-3 2”-150 class 316L Stainless flange, std mount
5627-13 3”-150 class ANSI, 316L Stainless
5627-23 4”-150 class ANSI, 316L Stainless
Flush Weld Tank Shell
1777-2 | Weld-in tank shell, short length sensor, 316L SS, length 1-7/8” (48 mm) Use for single wall (non-insulated) tank only! |
1777 | Weld-in tank shell, std length sensor, 316L SS, length 6-1/4” (159 mm) Use for single wall or insulated wall up to 4-1/2” thick |
1777-3 | Weld-in tank shell, long length sensor, 316L SS, length 8-1/2” (216 mm) Use for insulated wall up to 6-3/4” thick |
Download Installation Instructions
5668-1 Short mount fixture
5668-2 Standard mount fixture
5668-3 Long mount fixture
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov