Level Transmitters

Home » Products » Level Transmitters » Electronic » 58 Series ES3 Sanitary Level Transmitter

58 Series ES3 Sanitary Level Transmitter

  • Standard flush mount
  • 4:1 turn down 
  • Multiple process connections
  • Electronic (4 mA to 20 mA) output
  • Consistent output during CIP cycles
  • HART® protocol output available
  • All transmitters are fully temperature compensated

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

ORDERING INFORMATION

SERIES 58          
PROCESS CONNECTIONS 01 KING Short 02 KING Standard 03 KING Long
OPTIONS 01 Standard options 04 Hart® protocol    
02 Transparent cover 06 Transparent cover + Hart®    
SPAN RANGE 01 1.5 psi to 5.8 psi 03 14.5 psi to 58 psi 05 87 psi to 350 psi
02 5.8 psi to 23.2 psi 04 29 psi to 145 psi    

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SPECIFICATIONS

Span adjustment range* Transmitter turndown ratio is 4:1 for all ranges.
Nominal
0–5.8 psig
0–23 psig
0–58 psig
0–145 psig
0–350 psig
Minimum
0–1.45 psig
5.8 psig
0–14.5 psig
0–29 psig
0–87 psig
Range of Adjustment
0–40 inH2O through 0 – 160 inH2O
0–1 m through 0–4 m water
0–160 inH2O through 0 – 630 inH2O 0–4 m through 0– 16 m water
0–394 inH2O through 0–1575 inH2O / 
0–10 m through 0–40 m water
Operating limit (maximum pressure) Pressure above 300% nominal range (over-range) will result in damage to the transmitter (200% may cause a shift in calibration).
Accuracy Less than ± 0.20% Adjusted Span
Includes linearity, hysteresis, non-repeatability errors.
Pressure media Gas or liquids compatible with Hastelloy (diaphragm); Silicone rubber (o-ring). All other wetted parts 316L.
Electrical Input (excitation): 14 Vdc to36 Vdc
Output (mAdc): 4 mA to 20 mA
HART® protocol (optional)
Linearity (worst case) Less than ± 0.13% full scale
Hysteresis (worst case)
Less than 0.05% full scale
Non-repeatability (worst case) Less than 0.02% full scale
Operating temperature range -4 °F to 212 °F / -20 °C to 100 °C

* IMPORTANT! Accuracy, linearity, and non-repeatability values are based on adjusted span range.

Options & Accessories

Available in 304 SS only

5872-1-2    Adapter, NPT-M (male) thd, use std. sensor
5872-2-2    Adapter, NPT-F (female) thd, use std. sensor

5878-1       Short Anderson shell, use standard sensor
5878-2       Long Anderson shell, use long sensor

Download Installation Instructions

Adapters available in 304 SS only

5640-1       Short Cherry-Burrell shell, use standard sensor
5640-2       Long Cherry-Burrell shell, use long sensor

Download the Installation Instructions

5665-1   Continental/Floe/Wizard shell, use standard sensor

Download Installation Instructions

5527-3        2”- flange 316L Stainless, short mount
5527-5        1-1/2”- flange 316L Stainless, short mount
5527-13      3”- flange 316L Stainless, short mount
5527-15      1”- flange 316L Stainless, short mount
5527-23      4”- flange 316L Stainless, short mount
5627-3        2”-150 class 316L Stainless flange, std mount
5627-13      3”-150 class ANSI, 316L Stainless
5627-23      4”-150 class ANSI, 316L Stainless
 

Flush Weld Tank Shell

1777-2   Weld-in tank shell, short length sensor, 316L SS, length 1-7/8” (48 mm)
Use for single wall (non-insulated) tank only!
1777 Weld-in tank shell, std length sensor, 316L SS, length 6-1/4” (159 mm)
Use for single wall or insulated wall up to 4-1/2” thick
1777-3   Weld-in tank shell, long length sensor, 316L SS, length 8-1/2” (216 mm)
Use for insulated wall up to 6-3/4” thick

 

Download Installation Instructions

5905-1     2” Ext. Foxboro/Rosemount, use standard sensor *
5905-2     6” Ext. Foxboro/Rosemount, use long sensor *

* Minimum 5 pcs order required (special)

1749-35-1    Liquid scale adapter package, use long sensor

2584-4   Shell plug, fits short shell
2584-3 Shell plug, fits standard shell, tri-clamp,
& short adapters
2584-6 Shell plug, fits long shell, long adapters

5664-1    Shell face protector, fits all weld-in shells

5641-1       Short Tank-Mate shell, use standard sensor
5641-2       Long Tank-Mate shell, use long sensor

1749-25    Tri-clamp MP-2”, 316L Stainless Steel; short length sensor
1749-27    Tri-clamp MP-2”, 316L Stainless Steel; standard length sensor

WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov