Home » Products » Level Transmitters » Mechanical » 450 Series AcraSensor Level Transmitter

450 Series AcraSensor Level Transmitter

  • Flush mounting sanitary design  
  • Pneumatic output, or electronic (4 mA to 20 mA) output when paired with KING-GAGE 860 Series Sensor Control or 868 Series D/P Purge Control
  • Field replaceable sensor diaphragm
  • Stable output during CIP cycles
  • FDA-approved silicone rubber O-ring seal forms a crevice-free, positive compression seal between the diaphragm probe and mounting shell
  • Flush weld mountings are available with product contact surfaces of 
  • 316L Stainless Steel
  • Meets the requirements of 3-A

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

ORDERING INFORMATION

SERIES 450  
MOUNTING APPLICATION 1 Short mount (single wall, non-insulated tank) * 2 Standard mount (insulated wall up to 4.5" / 114 mm; or adapter for non-KING-GAGE “short” shell) ** 3 Long mount (insulated wall up to 6.75" / 171 mm; or adapter for non-KING-GAGE “standard” shell) ***
OUTPUT/CONNECTIONS 0 Pneumatic (pressure) 1/4" tube Swagelok 3 Electronic (4-20 mA), 1/4" tube Swagelok    
1 Pneumatic (pressure) 1/4" tube Polyflo 4 Electronic (4-20 mA) 1/4" tube Polyflo    
RANGE 02 0-2 psid / 0-0.14 bar 15 0-15 psid / 0-1.03 bar 38 Pneumatic, includes SafeGard option (25-650” range)
05 0-5 psid / 0-0.3 bar 30 0-30 psid / 0-2.06 bar 48 Pneumatic, includes SafeGard option (650-1750” range)
10 0-10 psid / 0-0.69 bar 50 0-50 psid / 0-3.44 bar 58 Pneumatic, none

NOTE: AcraSensor packages listed include diaphragm sensing unit, 860 Series Sensor Control or 868 Series D/P Purge Control, Swagelok or PolyFlo fittings, and bundled 3-tube airline cable
*       Use with weld-in shell 1777-2 or to fit 2" sanitary clamp fitting adapter
**      Use with weld-in shell 1777 or to fit adapter for non-KING-GAGE “short” shell
***     Use with weld-in shell 1777-3 or to fit adapter for non-KING-GAGE “standard” shell

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SPECIFICATIONS

Sensitivity Less than .001 psi (±.02 inH2O .508 mm water)
Repeatability Better than ±.002 psi (± .05 inH2O/ 1.27 mm water)
Accuracy ±.007 psi (±0.2 inH2O / .508 mm water)
Temperature range 30 ° F to 300 ° F (0 °C to 149 °C)
Pressure range Sensor is a 1:1 pneumatic force balance diaphragm capable of repeating hydrostatic pressure as an equivalent pneumatic output. Functional pressure limit is 130 psi (or 3598 inches @ 1.00 specific gravity) determined by supply pressure (35–150 psi) less 20 psi.
Maximum depth measurement 1937 inH2O (49.0 m water)
Wetted materials Silicone rubber O-ring (meets the requirements of 3-A)
Titanium diaphragm, commercially pure (meets the requirements of 3-A 74-07).
Optional diaphragm materials: Silicone rubber
Fittings/adapter wetted surfaces are typically 316L Stainless Steel (as supplied by KING-GAGE).
Air consumption Total air consumption of sensor package (including sensor control) is less than 10 CFH or 0.16 scfm.
D/P sensor control combined accuracy* 0 psid to 5 psid transmitter/control ±0.34% full scale
0 psid to 10 psid transmitter/control ±0.27% full scale
0 psid to 15 psid transmitter/control ±0.24% full scale
0 psid to 30 psid transmitter/control ±0.22% full scale
0 psid to 50 psid transmitter/control ±0.21% full scale
Voltage supply requirements 14 Vdc tp 40 Vdc (unregulated) to power signal loop using 868 D/P Sensor Control.
Compressed air supply requirements 35 psig to 150 psig (2.4–10.3 bar); clean, dry air (or inert gas)

* Combined accuracy refers to the primary accuracy of the sensor in combination with the secondary accuracy of the D/P transmitter.

Options & Accessories

  • Better than ±0.02% span repeatability
  • Also offered in hybrid versions combined with an air flow control for pneumatic sensors or downpipe (bubbler) systems

More details on 860 Series Sensor Control

  • 4 mA to 20 mA output for broad compatibility
  • Better than ±0.02% span repeatability
  • Piezoresistive technology for enhanced stability
  • Also offered in hybrid versions combined with an air flow control for pneumatic sensors or downpipe (bubbler) systems

More details on 868 Series Differential Pressure Sensor Control

Use for interconnection between AcraSensor and Sensor Control

1766-15      Cable, 15 ft (4.5 m) total length, trimmed
8014-*         Cable quantity discount, minimum purchase 50 feet

* = Total length

1751 Clamp nut, 304 SS
1752-22-3 Acrasensor connector assembly (old)
1752-30-3 Acrasensor connector assembly (new)
6554-40 O-ring, silicone rubber (standard)
   
1747-40 O-ring, Viton (special application)1
1786-40 O-ring, PTFE (special application)1
6554-44 O-ring, oversized (special application)1
   
5611-21 Acrasensor housing (short)
5611-22 Acrasensor housing (standard)
5611-23 Acrasensor housing (long)
7859-1 Post assembly short
7859-2 Post assembly standard
7859-3 Post assembly long
7899-3 Body (for rubber diaphragm)

 

1 Consult factory

7904-1         AS Titanium diaphragm assembly with Silicone o-ring 
S-1618-3      AS Titanium diaphragm assembly with PTFE o-ring
6448-12-5    Silicone (white rubber) diaphragm 2-pack (Rubber diaphragm is used with 7899-3 body)

Acrasensor (Titanium with Silicone rubber o-ring)

8999-1-4  Short length, titanium diaphragm
8999-2-4 Std length, titanium diaphragm
8999-3-4 Long length, titanium diaphragm

 

Acrasensor (Titanium diaphragm with PTFE o-ring)

8999-1-5 Short length, S-1618-3 diaphragm
8999-2-5 Std length, S-1618-3 diaphragm
8999-3-5 Long length, S-1618-3 diaphragm

 

Standard Length - Use with 1777 weld-in shell for single wall or insulated wall (up to 4.5” thick; also fits adaptors for non-KING-GAGE “short” shells.
Long Length - Use with1777-3 weld-in shell for Crepaco silo or other thicker wall (up to 6.75”) vessels; also fits adapters for non-KING-GAGE standard (insulated wall) shells.
Short Length - For single wall (non-insulated) tanks; fits KING-GAGE short shell.

NOTE: Laser-fused Titanium Diaphragm units are generally recommended for both sanitary and industrial applications.
 

Replacement D/P capsule (sensor/transmitter assembly) for Model 868 D/P Sensor Controls. Signal input connection is 1/4 NPT - part numbers below do not include fitting.

S-1565-1-5-1 D/P replacement capsule kit (0-2 psid)
S-1565-1-0-1 D/P replacement capsule kit (0-5 psid)
S-1565-1-1-1 D/P replacement capsule kit (0-10 psid)
S-1565-1-2-1 D/P replacement capsule kit (0-15 psid)
S-1565-1-3-1 D/P replacement capsule kit (0-30 psid)
S-1565-1-4-1  D/P replacement capsule kit (0-50 psid)
7333-10 Replacement filter element
7334-2 SafeGard service kit
7334-9 Air control section kit
7879-20 Vent generator
9316-4 O-ring for D/P top plate (868)

    
        
        
        
        

WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov