Process Indicators

Home » Products » Process Indicators » Electronic » 5111 Series LevelBAR Electronic Column Indicator

5111 Series LevelBAR Electronic Column Indicator

  • High visibility tank level display
  • Individually calibrated indicator scale
  • Electronic (4 mA to 20 mA) or pneumatic input
  • Direct replacement for manometer gauges

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

ORDERING INFORMATION

SERIES 5111 LevelBAR Electronic Column Indicator

INPUT TYPES/RANGES

   Pneumatic Input
   witth Internal
   D/P Transmitter

20 0-5 psid nominal range; Min. Full Scale:
0-69 in. water depth (0-1.8 m water);
Max. Full Scale: 0-138 in. water depth
(0-3.5 m water)
22 0-15 psid nominal range;
Min. Full Scale: 0-207 in. water
depth (0-5.3 m water);
Max. Full Scale: 0-415 in. water depth
(0-10.5 m water)
24 0-50 psid nominal range; Min. Full Scale:
0-692 in. water depth (0-17.6 m water);
Max. Full Scale: 0-1384 in. water depth
(0-35.1 m water)
21 0-10 psid nominal range; Min. Full Scale:
0-138 in. water depth (0-3.5 m water);
Max. Full Scale: 0-276 in. water depth
(0-7.0 m water)
23 0-30 psid nominal range;
Min. Full Scale: 0-415 in. water
depth (0-10.5 m water);
Max. Full Scale: 0-830 in. water depth
(0-21.0 m water)
25 0-2 psid nominal range; Min. Full Scale:
0-28 in. water depth (0-0.7 m water);Max.
Full Scale: 0-83 in. water depth (0-2.1 m water)
   mA Input 10 4-12 mAdc through 4-20 mAdc        
   Hand Pump
   Operation
   for Downpipe
   Purge*
30 0-5 psid w/ hand pump; Min. Full Scale:
0-69 in. water depth (0-1.8 m water);
Max. Full Scale: 0-138 in. water depth
(0-3.5 m water)
31 0-10 psid w/ hand pump;
Min. Full Scale: 0-138 in. water
depth (0-3.5 m water);
Max. Full Scale: 0-276 in. water depth
(0-7.0 m water)
35 0-2 psid w/ hand pump; Min. Full Scale:
0-28 in. water depth (0-0.7 m water);
Max. Full Scale: 0-83 in. water depth
(0-2.1 m water)

NOTES: Scale information must be supplied when order is placed
* Typical applications should not exceed 10 feet / 3 meters. Greater depth will require excessive hand pumping.

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SPECIFICATIONS

Display accuracy/resolution 1%
Display type 100-segment LED (light emitting diode)
Display length 10”/254 mm
Input power 100–240 Vac, 50/60 Hz
Output power 24 Vdc (transmitter excitation)
Input impedance (resistance) 150 ohm nominal (3.0 Vdc drop @ 20 mA)
Current limiting (overload) Automatic trip/reset circuit using PTC (positive temperature coefficient) resistor holds maximum current
level within operating range of internal components.
Temperature range (Environmental) 30 °F to 120 °F (-1 °C to 49 °C) operating range
Signal input (Electronic input model) 4–12 mAdc (min.) to 4–20 mAdc full scale range
Pressure ranges (D/P option models) 0–5, –10, –15, –30, –50 psid fixed range trans­mitter element (accepts clean, dry air/gas pressure input). Maximum
pressure rating is 300% FS. Minimum pressure range for proper opera­tion is 50% of nominal. The lowest acceptable
input pressure range is 0–2.5 psid using the 0–5 psid transducer element.
Transmitter accuracy (D/P option models) 0.5% FS
Output (D/P option models) 4–20 mAdc (assumes FSO)
Maximum load capacity
(D/P option models)
1400 ohms @ 40 Vdc (external power)
600 ohms @ 24 Vdc (internal power)
Physical data 304 Stainless Steel housing and cover with gasket seal, transparent polycarbonate display window. Intended to meet
splash proof requirements. The use of waterproof conduit hubs or fittings may be required during installation. Not rated
for continuous explosion hazard areas.

Options & Accessories

7469-21-0       500 mA 250V fast acting (AGC) fuse, 0.25 x 1.25 in, replacement 5-pack 
5858-2            2-terminal socket connector
5858-3           3-terminal socket connector
 

A standard 1-unit scale is included in the package price listed for LevelBAR models. The LevelBAR scale is custom marked in any specified unit of measurement (gallons, liters, barrels, etc.). An optional 2-unit scale can combine any two different measurements such as weight and volume, or volume and depth.

When ordering, the following information must be supplied. If replacing an existing scale, also provide the original serial number.

    •     Specific Gravity (Density) of Tank Contents 
    •     Product Designation (tank contents)
    •     Description of Tank (e.g., Walker 6000 gal silo)
    •    Tank Dimensions
    •    Tank Name (to be noted on scale)
    •    Pressure Range of transmitter or LevelBAR
    •    Scaling Units (e.g., lbs, gals, liters, etc.)

Scales are calculated for the individual tank geometry and product specific gravity. Scaling adjustments setting (REF HIGH) is noted on the side of the scale. This is used to set the full scale display based on pressure range of the transmitter and maximum pressure created by depth of tank product.
Tank Calibrations - The LevelBAR indicator should not be used for physical water calibrations of tanks. Use of a pressure standard or other high accuracy pressure measurement instrument is recommended.
 

5980-11     Replacement 1-unit LevelBAR scale assembly 
5980-21     Replacement 2-unit LevelBAR scale assembly
 

WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov